{"product_id":"clamp-current-transformer-lmck-24-2005a-accuracy-class-1-split-core-clamp-on","title":"Clamp Current Transformer LMCK-24 • 200\/5A • Accuracy Class 1 • Split-Core \/ Clamp-On","description":"\u003ch2 data-start=\"373\" data-end=\"395\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch3 data-start=\"397\" data-end=\"411\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"412\" data-end=\"793\"\u003eThe \u003cstrong data-start=\"416\" data-end=\"451\"\u003eLMCK-24 200\/5A Accuracy Class 1\u003c\/strong\u003e is a clamp-on (split-core) current transformer from the LMCK series, designed for accurate measurement of alternating current (AC) in electrical circuits. With a primary rating of 200 A and secondary of 5 A, this CT provides reliable current monitoring for industrial, commercial, or residential systems where a Class 1 accuracy is required.\u003c\/p\u003e\n\u0026lt; data-start=\"795\" data-end=\"798\"\u0026gt;\n\u003ch3 data-start=\"800\" data-end=\"816\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"818\" data-end=\"1673\"\u003e\n\u003cli data-start=\"818\" data-end=\"840\"\u003e\n\u003cp data-start=\"820\" data-end=\"840\"\u003e\u003cstrong data-start=\"820\" data-end=\"829\"\u003eModel\u003c\/strong\u003e: LMCK-24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"841\" data-end=\"881\"\u003e\n\u003cp data-start=\"843\" data-end=\"881\"\u003e\u003cstrong data-start=\"843\" data-end=\"869\"\u003ePrimary Current Rating\u003c\/strong\u003e: 200 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"948\"\u003e\n\u003cp data-start=\"884\" data-end=\"948\"\u003e\u003cstrong data-start=\"884\" data-end=\"912\"\u003eSecondary Current Rating\u003c\/strong\u003e: 5 A AC — giving a ratio of 200:5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"1061\"\u003e\n\u003cp data-start=\"951\" data-end=\"1061\"\u003e\u003cstrong data-start=\"951\" data-end=\"969\"\u003eAccuracy Class\u003c\/strong\u003e: \u003cstrong data-start=\"971\" data-end=\"978\"\u003e1.0\u003c\/strong\u003e — meaning it will have a maximum permissible error of ±1% under rated conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1175\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1175\"\u003e\u003cstrong data-start=\"1064\" data-end=\"1074\"\u003eDesign\u003c\/strong\u003e: Split-core \/ clamp-on — easy installation around existing conductors without breaking the circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1176\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1178\" data-end=\"1378\"\u003e\u003cstrong data-start=\"1178\" data-end=\"1201\"\u003eCore \/ Opening Size\u003c\/strong\u003e: Approx. 24 mm inner aperture (same “24” in LMCK-24 series suggests ~24 mm window) based on similar models from LMCK split-core CT line. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1531\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1392\"\u003eHousing\u003c\/strong\u003e: Flame-retardant plastic, moisture-protected, stable in performance, requires minimal maintenance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1532\" data-end=\"1673\"\u003e\n\u003cp data-start=\"1534\" data-end=\"1673\"\u003e\u003cstrong data-start=\"1534\" data-end=\"1556\"\u003eSelf-locking clamp\u003c\/strong\u003e: Facilitates safe, secure installation; portable and suitable for retrofits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1675\" data-end=\"1678\"\u0026gt;\n\u003ch3 data-start=\"1680\" data-end=\"1708\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1710\" data-end=\"2452\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1710\" data-end=\"1752\"\u003e\n\u003ctr data-start=\"1710\" data-end=\"1752\"\u003e\n\u003cth data-start=\"1710\" data-end=\"1726\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1726\" data-end=\"1752\" data-col-size=\"md\"\u003eDetail \/ Typical Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1798\" data-end=\"2452\"\u003e\n\u003ctr data-start=\"1798\" data-end=\"1833\"\u003e\n\u003ctd data-start=\"1798\" data-end=\"1821\" data-col-size=\"sm\"\u003ePrimary Current (In)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1821\" data-end=\"1833\"\u003e200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1834\" data-end=\"1869\"\u003e\n\u003ctd data-start=\"1834\" data-end=\"1859\" data-col-size=\"sm\"\u003eSecondary Current (Is)\u003c\/td\u003e\n\u003ctd data-start=\"1859\" data-end=\"1869\" data-col-size=\"md\"\u003e5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1870\" data-end=\"1902\"\u003e\n\u003ctd data-start=\"1870\" data-end=\"1893\" data-col-size=\"sm\"\u003eTransformation Ratio\u003c\/td\u003e\n\u003ctd data-start=\"1893\" data-end=\"1902\" data-col-size=\"md\"\u003e200:5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1903\" data-end=\"1927\"\u003e\n\u003ctd data-start=\"1903\" data-end=\"1920\" data-col-size=\"sm\"\u003eAccuracy Class\u003c\/td\u003e\n\u003ctd data-start=\"1920\" data-end=\"1927\" data-col-size=\"md\"\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1928\" data-end=\"1980\"\u003e\n\u003ctd data-start=\"1928\" data-end=\"1954\" data-col-size=\"sm\"\u003eInner Diameter \/ Window\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1954\" data-end=\"1980\"\u003e~24 mm (for conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1981\" data-end=\"2011\"\u003e\n\u003ctd data-start=\"1981\" data-end=\"1988\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"1988\" data-end=\"2011\" data-col-size=\"md\"\u003eSplit-core clamp-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2012\" data-end=\"2084\"\u003e\n\u003ctd data-start=\"2012\" data-end=\"2031\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"2031\" data-end=\"2084\" data-col-size=\"md\"\u003eFlame retardant plastic (UL-94 V-0 or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2085\" data-end=\"2173\"\u003e\n\u003ctd data-start=\"2085\" data-end=\"2110\" data-col-size=\"sm\"\u003eProtection \/ Enclosure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2110\" data-end=\"2173\"\u003eMoisture protected; rated for indoor electrical environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2174\" data-end=\"2243\"\u003e\n\u003ctd data-start=\"2174\" data-end=\"2196\" data-col-size=\"sm\"\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2196\" data-end=\"2243\" data-col-size=\"md\"\u003eTypically 50\/60 Hz (confirm with datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2244\" data-end=\"2336\"\u003e\n\u003ctd data-start=\"2244\" data-end=\"2260\" data-col-size=\"sm\"\u003eBurden \/ Load\u003c\/td\u003e\n\u003ctd data-start=\"2260\" data-end=\"2336\" data-col-size=\"md\"\u003eTo be specified (manufacturer will supply maximum VA load for secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2337\" data-end=\"2452\"\u003e\n\u003ctd data-start=\"2337\" data-end=\"2352\" data-col-size=\"sm\"\u003eSafety Notes\u003c\/td\u003e\n\u003ctd data-start=\"2352\" data-end=\"2452\" data-col-size=\"md\"\u003eSecondary must not be open circuit when primary energized; ensure proper insulation and mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt; data-start=\"2454\" data-end=\"2457\"\u0026gt;\n\u003ch3 data-start=\"2459\" data-end=\"2475\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2477\" data-end=\"2830\"\u003e\n\u003cli data-start=\"2477\" data-end=\"2560\"\u003e\n\u003cp data-start=\"2479\" data-end=\"2560\"\u003eEnergy monitoring and metering in switchboards, panels, and distribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2561\" data-end=\"2647\"\u003e\n\u003cp data-start=\"2563\" data-end=\"2647\"\u003eRetrofitting or adding measurement to existing circuits without power interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2648\" data-end=\"2724\"\u003e\n\u003cp data-start=\"2650\" data-end=\"2724\"\u003eUse with power meters, PLCs, monitoring \u0026amp; control systems, SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2725\" data-end=\"2830\"\u003e\n\u003cp data-start=\"2727\" data-end=\"2830\"\u003eMonitoring of motors, lighting, HVAC, and other electrical loads where accuracy class 1 is sufficient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"2832\" data-end=\"2835\"\u0026gt;\n\u003ch3 data-start=\"2837\" data-end=\"2873\"\u003eInstallation \u0026amp; Safety Guidelines\u003c\/h3\u003e\n\u003cul data-start=\"2875\" data-end=\"3392\"\u003e\n\u003cli data-start=\"2875\" data-end=\"2988\"\u003e\n\u003cp data-start=\"2877\" data-end=\"2988\"\u003eVerify that conductor fits comfortably through ~24 mm opening; avoid forcing or bending conductor unnaturally\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2989\" data-end=\"3153\"\u003e\n\u003cp data-start=\"2991\" data-end=\"3153\"\u003eAlways ensure secondary is terminated (connected to meter \/ load); never leave secondary open during operation—this can lead to dangerous overvoltage and damage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3154\" data-end=\"3205\"\u003e\n\u003cp data-start=\"3156\" data-end=\"3205\"\u003eMount securely; close and lock clamp completely\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3206\" data-end=\"3319\"\u003e\n\u003cp data-start=\"3208\" data-end=\"3319\"\u003eAvoid installing in high ambient temperature beyond spec, very humid or corrosive environments (unless rated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3320\" data-end=\"3392\"\u003e\n\u003cp data-start=\"3322\" data-end=\"3392\"\u003eUse proper wire \/ cable protection at the entry points to avoid wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"3394\" data-end=\"3397\"\u0026gt;\n\u003ch3 data-start=\"3399\" data-end=\"3411\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"3413\" data-end=\"3715\"\u003e\n\u003cli data-start=\"3413\" data-end=\"3491\"\u003e\n\u003cp data-start=\"3415\" data-end=\"3491\"\u003eNon-intrusive installation saves labour and risk (no disconnection needed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3492\" data-end=\"3606\"\u003e\n\u003cp data-start=\"3494\" data-end=\"3606\"\u003eClass-1 accuracy gives reliable readings for general metering \/ billing where higher precision isn’t necessary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3607\" data-end=\"3659\"\u003e\n\u003cp data-start=\"3609\" data-end=\"3659\"\u003eDurable, low maintenance, consistent performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3660\" data-end=\"3715\"\u003e\n\u003cp data-start=\"3662\" data-end=\"3715\"\u003eWidely compatible with standard measurement devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54139411071273,"sku":"dfl1789525210425","price":11.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/3140\/8425\/files\/clamp-current-transformer-lmck-24-2005a-accuracy-class-1-split-core-clamp-on_1.jpg?v=1789525215","url":"https:\/\/neutraltonedcladstore.shop\/products\/clamp-current-transformer-lmck-24-2005a-accuracy-class-1-split-core-clamp-on","provider":"My Store","version":"1.0","type":"link"}