{"product_id":"chint-nxm-630s4300-mccb-600a-3p-50ka-molded-case-circuit-breaker","title":"CHINT NXM-630S\/4300 MCCB – 600A, 3P, 50kA Molded Case Circuit Breaker","description":"\u003cp data-start=\"279\" data-end=\"645\"\u003e\u003cstrong data-start=\"279\" data-end=\"303\"\u003eProduct Description:\u003c\/strong\u003e\u003cbr data-start=\"303\" data-end=\"306\"\u003eDesigned for high-demand industrial and commercial electrical systems, the \u003cstrong data-start=\"381\" data-end=\"414\"\u003eCHINT NXM-630S\/4300 600A MCCB\u003c\/strong\u003e offers robust protection and long-lasting performance. Rated for \u003cstrong data-start=\"480\" data-end=\"488\"\u003e600A\u003c\/strong\u003e, this molded case circuit breaker ensures safe and efficient power control in applications ranging from factory floors to infrastructure-grade switchboards.\u003c\/p\u003e\n\u003cp data-start=\"647\" data-end=\"933\"\u003eWith a \u003cstrong data-start=\"654\" data-end=\"691\"\u003ebreaking capacity of 50kA at 230V\u003c\/strong\u003e and \u003cstrong data-start=\"696\" data-end=\"712\"\u003e36kA at 400V\u003c\/strong\u003e, this 3-pole breaker is built for critical power distribution networks. It features a \u003cstrong data-start=\"799\" data-end=\"829\"\u003ethermal-magnetic trip unit\u003c\/strong\u003e and a \u003cstrong data-start=\"836\" data-end=\"861\"\u003edurable NXM-630 frame\u003c\/strong\u003e, while complying fully with \u003cstrong data-start=\"890\" data-end=\"908\"\u003eIEC\/EN 60947-2\u003c\/strong\u003e international standards.\u003c\/p\u003e\n\u0026lt; data-start=\"935\" data-end=\"938\"\u0026gt;\n\u003cp data-start=\"940\" data-end=\"957\"\u003e\u003cstrong data-start=\"940\" data-end=\"957\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"958\" data-end=\"1350\"\u003e\n\u003cli data-start=\"958\" data-end=\"987\"\u003e\n\u003cp data-start=\"960\" data-end=\"987\"\u003e✅ \u003cstrong data-start=\"962\" data-end=\"980\"\u003eRated Current:\u003c\/strong\u003e 600A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"988\" data-end=\"1046\"\u003e\n\u003cp data-start=\"990\" data-end=\"1046\"\u003e✅ \u003cstrong data-start=\"992\" data-end=\"1014\"\u003eBreaking Capacity:\u003c\/strong\u003e 50kA (230V), 36kA (400V\/415V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1047\" data-end=\"1091\"\u003e\n\u003cp data-start=\"1049\" data-end=\"1091\"\u003e✅ \u003cstrong data-start=\"1051\" data-end=\"1070\"\u003eVoltage Rating:\u003c\/strong\u003e Up to 800V AC (Ui)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1134\"\u003e\n\u003cp data-start=\"1094\" data-end=\"1134\"\u003e✅ \u003cstrong data-start=\"1096\" data-end=\"1132\"\u003eFixed Thermal-Magnetic Trip Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1135\" data-end=\"1186\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1186\"\u003e✅ \u003cstrong data-start=\"1139\" data-end=\"1159\"\u003e3P Configuration\u003c\/strong\u003e – Three-phase protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1187\" data-end=\"1221\"\u003e\n\u003cp data-start=\"1189\" data-end=\"1221\"\u003e✅ \u003cstrong data-start=\"1191\" data-end=\"1219\"\u003ePush-to-Trip Test Button\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1284\"\u003e\n\u003cp data-start=\"1224\" data-end=\"1284\"\u003e✅ \u003cstrong data-start=\"1226\" data-end=\"1245\"\u003eCertifications:\u003c\/strong\u003e CE, KEMA, EAC, IEC 60947-2 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1285\" data-end=\"1350\"\u003e\n\u003cp data-start=\"1287\" data-end=\"1350\"\u003e✅ \u003cstrong data-start=\"1289\" data-end=\"1318\"\u003eSturdy NXM-630 Frame Size\u003c\/strong\u003e – Ideal for high-load systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1352\" data-end=\"1355\"\u0026gt;\n\u003cp data-start=\"1357\" data-end=\"1388\"\u003e\u003cstrong data-start=\"1357\" data-end=\"1386\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1389\" data-end=\"1899\"\u003e\n\u003cli data-start=\"1389\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1417\"\u003e\u003cstrong data-start=\"1391\" data-end=\"1401\"\u003eModel:\u003c\/strong\u003e NXM-630S\/4300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1450\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1450\"\u003e\u003cstrong data-start=\"1420\" data-end=\"1443\"\u003eRated Current (In):\u003c\/strong\u003e 600A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1451\" data-end=\"1494\"\u003e\n\u003cp data-start=\"1453\" data-end=\"1494\"\u003e\u003cstrong data-start=\"1453\" data-end=\"1487\"\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 800V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1495\" data-end=\"1530\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1530\"\u003e\u003cstrong data-start=\"1497\" data-end=\"1524\"\u003eImpulse Voltage (Uimp):\u003c\/strong\u003e 8kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1531\" data-end=\"1563\"\u003e\n\u003cp data-start=\"1533\" data-end=\"1563\"\u003e\u003cstrong data-start=\"1533\" data-end=\"1553\"\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1564\" data-end=\"1669\"\u003e\n\u003cp data-start=\"1566\" data-end=\"1601\"\u003e\u003cstrong data-start=\"1566\" data-end=\"1599\"\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1604\" data-end=\"1669\"\u003e\n\u003cli data-start=\"1604\" data-end=\"1618\"\u003e\n\u003cp data-start=\"1606\" data-end=\"1618\"\u003e230V: 50kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1621\" data-end=\"1635\"\u003e\n\u003cp data-start=\"1623\" data-end=\"1635\"\u003e240V: 50kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1652\"\u003e\n\u003cp data-start=\"1640\" data-end=\"1652\"\u003e400V: 36kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1655\" data-end=\"1669\"\u003e\n\u003cp data-start=\"1657\" data-end=\"1669\"\u003e415V: 36kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1670\" data-end=\"1762\"\u003e\n\u003cp data-start=\"1672\" data-end=\"1706\"\u003e\u003cstrong data-start=\"1672\" data-end=\"1704\"\u003eBreaking Capacity (Icu\/Ics):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1709\" data-end=\"1762\"\u003e\n\u003cli data-start=\"1709\" data-end=\"1734\"\u003e\n\u003cp data-start=\"1711\" data-end=\"1734\"\u003e230\/240V: 50kA \/ 30kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1737\" data-end=\"1762\"\u003e\n\u003cp data-start=\"1739\" data-end=\"1762\"\u003e400\/415V: 36kA \/ 20kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1763\" data-end=\"1808\"\u003e\n\u003cp data-start=\"1765\" data-end=\"1808\"\u003e\u003cstrong data-start=\"1765\" data-end=\"1791\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1809\" data-end=\"1855\"\u003e\n\u003cp data-start=\"1811\" data-end=\"1855\"\u003e\u003cstrong data-start=\"1811\" data-end=\"1829\"\u003eMounting Type:\u003c\/strong\u003e Fixed (front-connected)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1856\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1899\"\u003e\u003cstrong data-start=\"1858\" data-end=\"1882\"\u003eStandard Compliance:\u003c\/strong\u003e IEC\/EN 60947-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1901\" data-end=\"1904\"\u0026gt;\n\u003cp data-start=\"1906\" data-end=\"1925\"\u003e\u003cstrong data-start=\"1906\" data-end=\"1923\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1926\" data-end=\"2118\"\u003e\n\u003cli data-start=\"1926\" data-end=\"1960\"\u003e\n\u003cp data-start=\"1928\" data-end=\"1960\"\u003eHigh-load industrial equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1961\" data-end=\"1989\"\u003e\n\u003cp data-start=\"1963\" data-end=\"1989\"\u003eMain distribution panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1990\" data-end=\"2021\"\u003e\n\u003cp data-start=\"1992\" data-end=\"2021\"\u003eGenerators and transformers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2022\" data-end=\"2056\"\u003e\n\u003cp data-start=\"2024\" data-end=\"2056\"\u003eCommercial facility protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2057\" data-end=\"2083\"\u003e\n\u003cp data-start=\"2059\" data-end=\"2083\"\u003eElectrical substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2084\" data-end=\"2118\"\u003e\n\u003cp data-start=\"2086\" data-end=\"2118\"\u003eHVAC and motor control centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":54138619003177,"sku":"osq1789524767015","price":170.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/3140\/8425\/files\/chint-nxm-630s4300-mccb-600a-3p-50ka-molded-case-circuit-breaker_1.jpg?v=1789524771","url":"https:\/\/neutraltonedcladstore.shop\/products\/chint-nxm-630s4300-mccb-600a-3p-50ka-molded-case-circuit-breaker","provider":"My Store","version":"1.0","type":"link"}