{"product_id":"chint-nxm-250s3300-mccb-250a-3p-36ka-molded-case-circuit-breaker","title":"CHINT NXM-250S\/3300 MCCB – 250A, 3P, 36kA Molded Case Circuit Breaker","description":"\u003cp data-start=\"261\" data-end=\"632\"\u003e\u003cstrong data-start=\"261\" data-end=\"285\"\u003eProduct Description:\u003c\/strong\u003e\u003cbr data-start=\"285\" data-end=\"288\"\u003eThe \u003cstrong data-start=\"292\" data-end=\"325\"\u003eCHINT NXM-250S\/3300 250A MCCB\u003c\/strong\u003e is a powerful and compact molded case circuit breaker built for high-demand electrical systems. With a breaking capacity of \u003cstrong data-start=\"450\" data-end=\"466\"\u003e36kA at 400V\u003c\/strong\u003e, this 3-pole breaker ensures reliable protection against overloads, short circuits, and electrical faults in industrial, commercial, and infrastructure environments.\u003c\/p\u003e\n\u003cp data-start=\"634\" data-end=\"904\"\u003eEquipped with a \u003cstrong data-start=\"650\" data-end=\"680\"\u003ethermal-magnetic trip unit\u003c\/strong\u003e, this MCCB offers fast fault response while maintaining steady operation under rated loads. It complies with \u003cstrong data-start=\"790\" data-end=\"818\"\u003eIEC\/EN 60947-2 standards\u003c\/strong\u003e and comes in a durable, compact frame suitable for space-limited panel installations.\u003c\/p\u003e\n\u0026lt; data-start=\"906\" data-end=\"909\"\u0026gt;\n\u003cp data-start=\"911\" data-end=\"928\"\u003e\u003cstrong data-start=\"911\" data-end=\"928\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"929\" data-end=\"1280\"\u003e\n\u003cli data-start=\"929\" data-end=\"958\"\u003e\n\u003cp data-start=\"931\" data-end=\"958\"\u003e✅ \u003cstrong data-start=\"933\" data-end=\"951\"\u003eRated Current:\u003c\/strong\u003e 250A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"1009\"\u003e\n\u003cp data-start=\"961\" data-end=\"1009\"\u003e✅ \u003cstrong data-start=\"963\" data-end=\"990\"\u003eHigh Breaking Capacity:\u003c\/strong\u003e 36kA at 400\/415V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1010\" data-end=\"1049\"\u003e\n\u003cp data-start=\"1012\" data-end=\"1049\"\u003e✅ \u003cstrong data-start=\"1014\" data-end=\"1033\"\u003eVoltage Rating:\u003c\/strong\u003e Up to 800V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1050\" data-end=\"1098\"\u003e\n\u003cp data-start=\"1052\" data-end=\"1098\"\u003e✅ \u003cstrong data-start=\"1054\" data-end=\"1073\"\u003eTrip Mechanism:\u003c\/strong\u003e Fixed thermal-magnetic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1099\" data-end=\"1140\"\u003e\n\u003cp data-start=\"1101\" data-end=\"1140\"\u003e✅ \u003cstrong data-start=\"1103\" data-end=\"1126\"\u003ePole Configuration:\u003c\/strong\u003e 3P (3-pole)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1141\" data-end=\"1177\"\u003e\n\u003cp data-start=\"1143\" data-end=\"1177\"\u003e✅ \u003cstrong data-start=\"1145\" data-end=\"1175\"\u003ePush-to-trip test function\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1178\" data-end=\"1233\"\u003e\n\u003cp data-start=\"1180\" data-end=\"1233\"\u003e✅ \u003cstrong data-start=\"1182\" data-end=\"1201\"\u003eCertifications:\u003c\/strong\u003e CE, KEMA, EAC, IEC\/EN 60947-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1234\" data-end=\"1280\"\u003e\n\u003cp data-start=\"1236\" data-end=\"1280\"\u003e✅ \u003cstrong data-start=\"1238\" data-end=\"1280\"\u003eDurable and compact NXM-250 frame size\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1282\" data-end=\"1285\"\u0026gt;\n\u003cp data-start=\"1287\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1287\" data-end=\"1316\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1319\" data-end=\"1896\"\u003e\n\u003cli data-start=\"1319\" data-end=\"1347\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1347\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1331\"\u003eModel:\u003c\/strong\u003e NXM-250S\/3300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1380\"\u003e\n\u003cp data-start=\"1350\" data-end=\"1380\"\u003e\u003cstrong data-start=\"1350\" data-end=\"1373\"\u003eRated Current (In):\u003c\/strong\u003e 250A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1381\" data-end=\"1424\"\u003e\n\u003cp data-start=\"1383\" data-end=\"1424\"\u003e\u003cstrong data-start=\"1383\" data-end=\"1417\"\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 800V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1425\" data-end=\"1476\"\u003e\n\u003cp data-start=\"1427\" data-end=\"1476\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1470\"\u003eRated Impulse Withstand Voltage (Uimp):\u003c\/strong\u003e 8kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1511\"\u003e\n\u003cp data-start=\"1479\" data-end=\"1511\"\u003e\u003cstrong data-start=\"1479\" data-end=\"1499\"\u003eRated Frequency:\u003c\/strong\u003e 50Hz\/60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1512\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1514\" data-end=\"1549\"\u003e\u003cstrong data-start=\"1514\" data-end=\"1547\"\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1552\" data-end=\"1617\"\u003e\n\u003cli data-start=\"1552\" data-end=\"1566\"\u003e\n\u003cp data-start=\"1554\" data-end=\"1566\"\u003e230V: 50kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1569\" data-end=\"1583\"\u003e\n\u003cp data-start=\"1571\" data-end=\"1583\"\u003e240V: 50kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1600\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1600\"\u003e400V: 36kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1603\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1605\" data-end=\"1617\"\u003e415V: 36kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1618\" data-end=\"1730\"\u003e\n\u003cp data-start=\"1620\" data-end=\"1674\"\u003e\u003cstrong data-start=\"1620\" data-end=\"1672\"\u003eRated Short-Circuit Breaking Capacity (Icu\/Ics):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1677\" data-end=\"1730\"\u003e\n\u003cli data-start=\"1677\" data-end=\"1702\"\u003e\n\u003cp data-start=\"1679\" data-end=\"1702\"\u003e230\/240V: 50kA \/ 30kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1705\" data-end=\"1730\"\u003e\n\u003cp data-start=\"1707\" data-end=\"1730\"\u003e400\/415V: 36kA \/ 20kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1731\" data-end=\"1776\"\u003e\n\u003cp data-start=\"1733\" data-end=\"1776\"\u003e\u003cstrong data-start=\"1733\" data-end=\"1759\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1817\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1817\"\u003e\u003cstrong data-start=\"1779\" data-end=\"1792\"\u003eMounting:\u003c\/strong\u003e Fixed front connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1818\" data-end=\"1863\"\u003e\n\u003cp data-start=\"1820\" data-end=\"1863\"\u003e\u003cstrong data-start=\"1820\" data-end=\"1835\"\u003eCompliance:\u003c\/strong\u003e IEC 60947-2, GB\/T 14048.2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1896\"\u003e\n\u003cp data-start=\"1866\" data-end=\"1896\"\u003e\u003cstrong data-start=\"1866\" data-end=\"1881\"\u003eDimensions:\u003c\/strong\u003e NXM250 frame\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1898\" data-end=\"1901\"\u0026gt;\n\u003cp data-start=\"1903\" data-end=\"1922\"\u003e\u003cstrong data-start=\"1903\" data-end=\"1920\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1923\" data-end=\"2143\"\u003e\n\u003cli data-start=\"1923\" data-end=\"1961\"\u003e\n\u003cp data-start=\"1925\" data-end=\"1961\"\u003eMain switchboards and power panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1962\" data-end=\"1994\"\u003e\n\u003cp data-start=\"1964\" data-end=\"1994\"\u003eIndustrial machines \u0026amp; motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1995\" data-end=\"2026\"\u003e\n\u003cp data-start=\"1997\" data-end=\"2026\"\u003eHVAC and compressor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2027\" data-end=\"2063\"\u003e\n\u003cp data-start=\"2029\" data-end=\"2063\"\u003eDistribution boards in factories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2064\" data-end=\"2103\"\u003e\n\u003cp data-start=\"2066\" data-end=\"2103\"\u003eBackup generator circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2104\" data-end=\"2143\"\u003e\n\u003cp data-start=\"2106\" data-end=\"2143\"\u003eCommercial and building power grids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":54141482205481,"sku":"qup1789528792719","price":39.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/3140\/8425\/files\/chint-nxm-250s3300-mccb-250a-3p-36ka-molded-case-circuit-breaker_1.webp?v=1789528797","url":"https:\/\/neutraltonedcladstore.shop\/products\/chint-nxm-250s3300-mccb-250a-3p-36ka-molded-case-circuit-breaker","provider":"My Store","version":"1.0","type":"link"}