{"product_id":"chint-nxm-125s4300-mccb-63a-4p-36ka-molded-case-circuit-breaker","title":"CHINT NXM-125S\/4300 MCCB – 63A, 4P, 36kA Molded Case Circuit Breaker","description":"\u003cp data-start=\"282\" data-end=\"650\"\u003e\u003cstrong data-start=\"282\" data-end=\"306\"\u003eProduct Description:\u003c\/strong\u003e\u003cbr data-start=\"306\" data-end=\"309\"\u003eThe \u003cstrong data-start=\"313\" data-end=\"352\"\u003eCHINT NXM-125S\/4300 4-Pole 63A MCCB\u003c\/strong\u003e delivers reliable protection for \u003cstrong data-start=\"386\" data-end=\"424\"\u003ethree-phase + neutral (4P) systems\u003c\/strong\u003e, commonly used in balanced electrical installations for commercial, industrial, and infrastructure projects. With a breaking capacity of up to \u003cstrong data-start=\"568\" data-end=\"584\"\u003e36kA at 400V\u003c\/strong\u003e, this MCCB offers superior performance in a compact NXM125 frame.\u003c\/p\u003e\n\u003cp data-start=\"652\" data-end=\"923\"\u003eEquipped with a \u003cstrong data-start=\"668\" data-end=\"698\"\u003ethermal-magnetic trip unit\u003c\/strong\u003e, it safeguards circuits against both overloads and short circuits. The 4-pole configuration ensures full-phase and neutral protection, making it ideal for sensitive and mission-critical loads requiring neutral disconnection.\u003c\/p\u003e\n\u0026lt; data-start=\"925\" data-end=\"928\"\u0026gt;\n\u003cp data-start=\"930\" data-end=\"947\"\u003e\u003cstrong data-start=\"930\" data-end=\"947\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"948\" data-end=\"1340\"\u003e\n\u003cli data-start=\"948\" data-end=\"976\"\u003e\n\u003cp data-start=\"950\" data-end=\"976\"\u003e✅ \u003cstrong data-start=\"952\" data-end=\"970\"\u003eRated Current:\u003c\/strong\u003e 63A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"977\" data-end=\"1042\"\u003e\n\u003cp data-start=\"979\" data-end=\"1042\"\u003e✅ \u003cstrong data-start=\"981\" data-end=\"1011\"\u003e4-Pole Protection (3P + N)\u003c\/strong\u003e – Complete circuit isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1043\" data-end=\"1087\"\u003e\n\u003cp data-start=\"1045\" data-end=\"1087\"\u003e✅ \u003cstrong data-start=\"1047\" data-end=\"1069\"\u003eBreaking Capacity:\u003c\/strong\u003e 36kA @ 400\/415V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1088\" data-end=\"1132\"\u003e\n\u003cp data-start=\"1090\" data-end=\"1132\"\u003e✅ \u003cstrong data-start=\"1092\" data-end=\"1111\"\u003eVoltage Rating:\u003c\/strong\u003e Up to 800V AC (Ui)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1133\" data-end=\"1176\"\u003e\n\u003cp data-start=\"1135\" data-end=\"1176\"\u003e✅ \u003cstrong data-start=\"1137\" data-end=\"1151\"\u003eTrip Unit:\u003c\/strong\u003e Fixed thermal-magnetic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1177\" data-end=\"1213\"\u003e\n\u003cp data-start=\"1179\" data-end=\"1213\"\u003e✅ \u003cstrong data-start=\"1181\" data-end=\"1211\"\u003ePush-to-trip Test Function\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1214\" data-end=\"1275\"\u003e\n\u003cp data-start=\"1216\" data-end=\"1275\"\u003e✅ \u003cstrong data-start=\"1218\" data-end=\"1233\"\u003eCompliance:\u003c\/strong\u003e IEC\/EN 60947-2, CE, EAC, KEMA certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1340\"\u003e\n\u003cp data-start=\"1278\" data-end=\"1340\"\u003e✅ \u003cstrong data-start=\"1280\" data-end=\"1297\"\u003eCompact Size:\u003c\/strong\u003e NXM-125 Frame for easy panel integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1342\" data-end=\"1345\"\u0026gt;\n\u003cp data-start=\"1347\" data-end=\"1378\"\u003e\u003cstrong data-start=\"1347\" data-end=\"1376\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1379\" data-end=\"1919\"\u003e\n\u003cli data-start=\"1379\" data-end=\"1407\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1407\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1391\"\u003eModel:\u003c\/strong\u003e NXM-125S\/4300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1408\" data-end=\"1439\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1439\"\u003e\u003cstrong data-start=\"1410\" data-end=\"1433\"\u003eRated Current (In):\u003c\/strong\u003e 63A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1440\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1442\" data-end=\"1477\"\u003e\u003cstrong data-start=\"1442\" data-end=\"1452\"\u003ePoles:\u003c\/strong\u003e 4P (3-phase + neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1478\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1521\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1514\"\u003eRated Insulation Voltage (Ui):\u003c\/strong\u003e 800V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1563\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1563\"\u003e\u003cstrong data-start=\"1524\" data-end=\"1557\"\u003eRated Impulse Voltage (Uimp):\u003c\/strong\u003e 8kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1564\" data-end=\"1652\"\u003e\n\u003cp data-start=\"1566\" data-end=\"1601\"\u003e\u003cstrong data-start=\"1566\" data-end=\"1599\"\u003eRated Operating Voltage (Ue):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1604\" data-end=\"1652\"\u003e\n\u003cli data-start=\"1604\" data-end=\"1618\"\u003e\n\u003cp data-start=\"1606\" data-end=\"1618\"\u003e230V: 50kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1621\" data-end=\"1635\"\u003e\n\u003cp data-start=\"1623\" data-end=\"1635\"\u003e400V: 36kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1652\"\u003e\n\u003cp data-start=\"1640\" data-end=\"1652\"\u003e415V: 36kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1653\" data-end=\"1683\"\u003e\n\u003cp data-start=\"1655\" data-end=\"1683\"\u003e\u003cstrong data-start=\"1655\" data-end=\"1669\"\u003eFrequency:\u003c\/strong\u003e 50Hz \/ 60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1684\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1686\" data-end=\"1720\"\u003e\u003cstrong data-start=\"1686\" data-end=\"1718\"\u003eBreaking Capacity (Icu\/Ics):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1723\" data-end=\"1768\"\u003e\n\u003cli data-start=\"1723\" data-end=\"1744\"\u003e\n\u003cp data-start=\"1725\" data-end=\"1744\"\u003e230V: 50kA \/ 30kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1749\" data-end=\"1768\"\u003e400V: 36kA \/ 20kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1769\" data-end=\"1814\"\u003e\n\u003cp data-start=\"1771\" data-end=\"1814\"\u003e\u003cstrong data-start=\"1771\" data-end=\"1797\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1815\" data-end=\"1861\"\u003e\n\u003cp data-start=\"1817\" data-end=\"1861\"\u003e\u003cstrong data-start=\"1817\" data-end=\"1836\"\u003eMounting Style:\u003c\/strong\u003e Fixed front connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1862\" data-end=\"1919\"\u003e\n\u003cp data-start=\"1864\" data-end=\"1919\"\u003e\u003cstrong data-start=\"1864\" data-end=\"1883\"\u003eTrip Mechanism:\u003c\/strong\u003e Thermal-magnetic (non-adjustable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u0026lt; data-start=\"1921\" data-end=\"1924\"\u0026gt;\n\u003cp data-start=\"1926\" data-end=\"1951\"\u003e\u003cstrong data-start=\"1926\" data-end=\"1949\"\u003eIdeal Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1952\" data-end=\"2172\"\u003e\n\u003cli data-start=\"1952\" data-end=\"1998\"\u003e\n\u003cp data-start=\"1954\" data-end=\"1998\"\u003eCommercial and residential 3-phase systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1999\" data-end=\"2041\"\u003e\n\u003cp data-start=\"2001\" data-end=\"2041\"\u003eBalanced loads with neutral protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2042\" data-end=\"2070\"\u003e\n\u003cp data-start=\"2044\" data-end=\"2070\"\u003eHVAC and lighting panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2071\" data-end=\"2094\"\u003e\n\u003cp data-start=\"2073\" data-end=\"2094\"\u003eDistribution boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2095\" data-end=\"2127\"\u003e\n\u003cp data-start=\"2097\" data-end=\"2127\"\u003eIndustrial automation setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2128\" data-end=\"2172\"\u003e\n\u003cp data-start=\"2130\" data-end=\"2172\"\u003ePower panels with critical neutral loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":54138832847145,"sku":"lps1789524890742","price":40.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/3140\/8425\/files\/chint-nxm-125s4300-mccb-63a-4p-36ka-molded-case-circuit-breaker_1.jpg?v=1789524895","url":"https:\/\/neutraltonedcladstore.shop\/products\/chint-nxm-125s4300-mccb-63a-4p-36ka-molded-case-circuit-breaker","provider":"My Store","version":"1.0","type":"link"}