{"product_id":"abb-sj202t-2-pole-miniature-circuit-breaker-40a-c-curve-3ka-breaking-capacity-2taz144200r0404","title":"ABB SJ202T 2-Pole Miniature Circuit Breaker – 40A, C-Curve, 3kA Breaking Capacity (2TAZ144200R0404)","description":"\u003ch2 data-start=\"223\" data-end=\"252\"\u003e\u003cstrong data-start=\"226\" data-end=\"250\"\u003eDetailed Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"253\" data-end=\"598\"\u003eThe \u003cstrong data-start=\"257\" data-end=\"289\"\u003eABB SJ202T (2TAZ144200R0404)\u003c\/strong\u003e is a \u003cstrong data-start=\"295\" data-end=\"337\"\u003e2-pole Miniature Circuit Breaker (MCB)\u003c\/strong\u003e engineered to protect electrical circuits from \u003cstrong data-start=\"385\" data-end=\"417\"\u003eoverloads and short-circuits\u003c\/strong\u003e. With a \u003cstrong data-start=\"426\" data-end=\"447\"\u003e40A rated current\u003c\/strong\u003e and \u003cstrong data-start=\"452\" data-end=\"487\"\u003eC-curve tripping characteristic\u003c\/strong\u003e, it is suitable for medium-load circuits in \u003cstrong data-start=\"532\" data-end=\"595\"\u003eresidential, commercial, and light industrial installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"600\" data-end=\"1004\"\u003eFeaturing a \u003cstrong data-start=\"612\" data-end=\"637\"\u003e3kA breaking capacity\u003c\/strong\u003e, the SJ202T ensures fast disconnection during short-circuit events, safeguarding wiring and connected equipment. Its \u003cstrong data-start=\"755\" data-end=\"793\"\u003ecompact, DIN-rail mountable design\u003c\/strong\u003e allows for easy installation and maintenance, while the thermal–magnetic mechanism guarantees \u003cstrong data-start=\"888\" data-end=\"913\"\u003elong-term reliability\u003c\/strong\u003e. The 2-pole configuration (L1, L2) provides full-phase protection for two-phase systems.\u003c\/p\u003e\n\u003ch3 data-start=\"1006\" data-end=\"1028\"\u003e\u003cstrong data-start=\"1010\" data-end=\"1026\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1029\" data-end=\"1469\"\u003e\n\u003cli data-start=\"1029\" data-end=\"1054\"\u003e\n\u003cp data-start=\"1031\" data-end=\"1054\"\u003eModel: \u003cstrong data-start=\"1038\" data-end=\"1052\"\u003eABB SJ202T\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1055\" data-end=\"1091\"\u003e\n\u003cp data-start=\"1057\" data-end=\"1091\"\u003ePart Number: \u003cstrong data-start=\"1070\" data-end=\"1089\"\u003e2TAZ144200R0404\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1122\"\u003e\n\u003cp data-start=\"1094\" data-end=\"1122\"\u003ePoles: \u003cstrong data-start=\"1101\" data-end=\"1120\"\u003e2-Pole (L1, L2)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1123\" data-end=\"1149\"\u003e\n\u003cp data-start=\"1125\" data-end=\"1149\"\u003eRated Current: \u003cstrong data-start=\"1140\" data-end=\"1147\"\u003e40A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1150\" data-end=\"1181\"\u003e\n\u003cp data-start=\"1152\" data-end=\"1181\"\u003eTripping Curve: \u003cstrong data-start=\"1168\" data-end=\"1179\"\u003eC-Curve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1182\" data-end=\"1212\"\u003e\n\u003cp data-start=\"1184\" data-end=\"1212\"\u003eBreaking Capacity: \u003cstrong data-start=\"1203\" data-end=\"1210\"\u003e3kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1248\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1248\"\u003eVoltage Rating: \u003cstrong data-start=\"1231\" data-end=\"1246\"\u003e230\/400V AC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1249\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1251\" data-end=\"1286\"\u003eCompact DIN-rail mountable design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1287\" data-end=\"1351\"\u003e\n\u003cp data-start=\"1289\" data-end=\"1351\"\u003eThermal–magnetic protection for overloads and short-circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1352\" data-end=\"1423\"\u003e\n\u003cp data-start=\"1354\" data-end=\"1423\"\u003eSuitable for residential, commercial, and light industrial circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1424\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1469\"\u003eCompliant with \u003cstrong data-start=\"1441\" data-end=\"1467\"\u003eIEC\/EN 60898 standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Electrical Supplies Ghana","offers":[{"title":"Default Title","offer_id":54139955249449,"sku":"tmu1789525596982","price":10.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0960\/3140\/8425\/files\/abb-sj202t-2-pole-miniature-circuit-breaker-40a-c-curve-3ka-breaking-capacity-2t_1.jpg?v=1789525601","url":"https:\/\/neutraltonedcladstore.shop\/products\/abb-sj202t-2-pole-miniature-circuit-breaker-40a-c-curve-3ka-breaking-capacity-2taz144200r0404","provider":"My Store","version":"1.0","type":"link"}